United Kingdom version. Checks against the suggested limits in the UK National Annex to BS EN 1993-1-1 instead of US IBC values, with E = 210 GPa for steel as Eurocode 3 uses and UK section sizes. US version
Beam Deflection Calculator (UK)
Deflection of a steel or timber beam checked against the UK National Annex limits: span/200 for most beams, span/360 under brittle finishes, length/180 cantilevers.
The interactive tool loads here when JavaScript runs.
About this toolWhat is the Beam Deflection Calculator?
In the UK a steel beam is checked for deflection under the variable (imposed) load, and the limits come from the UK National Annex to BS EN 1993-1-1: span/360 for a beam carrying plaster or another brittle finish, span/200 for other beams, and length/180 for a cantilever. They are suggested values that the designer and client can agree to change, and they are not the same as the IBC limits the US version of this page uses. Pick UK NA in "Deflection limits from" and the table switches over.
Eurocode 3 takes the modulus of steel as 210 GPa, so this version starts there rather than at 200 GPa. The default case is a 203 x 133 x 25 UB (Iy 2,340 cm⁴ from the Blue Book) spanning 6 m with 6 kN/m of imposed load: it deflects 20.6 mm, which is span/291. That passes span/200 comfortably but fails span/360, so the same beam is fine under a profiled metal ceiling and too flexible under a plastered one.
The calculation is linear-elastic and ignores shear deformation. Use the characteristic imposed load, not the factored ultimate load, and remember that a structural engineer signs off the design for Building Regulations purposes.
- Seven standard support and load cases, including an off-centre point load
- Maximum deflection, its location, both end slopes, reactions and peak moment
- Deflection limit checks with utilisation from IBC Table 1604.3, the UK NA to BS EN 1993-1-1, IS 800 / IS 456 or NBC Part 9, plus optional bending stress from S
- Typical E presets for steel, stainless, aluminium, timber grades, glulam and concrete
- SI and US units with conversion in place, deflected-shape chart, copy and share link
Updated
How to use the Beam Deflection Calculator
- Choose SI or US units. The force unit can be kN or N, or kip or lbf; switching systems converts the numbers you already typed.
- Pick the support and load case. For an off-centre point load, enter its distance a from the left support.
- Enter the span and the load. For a uniform load include the beam's self-weight and any dead load, not only the live load.
- Pick a material to fill in a typical E, or type your own, then enter the second moment of area I about the bending axis. Add the section modulus S if you also want the bending stress.
- Read the maximum deflection, its position, the end slopes and the moment, then check the L/180, L/240 and L/360 table and the deflected-shape chart.
Worked examples
203 x 133 x 25 UB, 6 m span, plastered ceiling below
Input
Simply supported, 6 m, UDL 6 kN/m imposed, E 210 GPa, I 2,340 cm⁴, UK NA limits
Output
20.6 mm (span/291); span/360 allows 16.7 mm, so it fails; span/200 allows 30 mm
Under a brittle finish the beam is 24% over the limit. Moving up to a deeper section, or adding a midspan support, are the usual fixes.
Same beam at 5.5 m
Input
Simply supported, 5.5 m, UDL 6 kN/m imposed, E 210 GPa, I 2,340 cm⁴
Output
14.6 mm (span/378); passes span/360 at 95% of the 15.3 mm limit
Deflection grows with the fourth power of span, so losing half a metre removes about 30% of it.
Background and insight
All of these formulas come from integrating the Euler-Bernoulli beam equation, E I y'' = M(x), twice and fixing the constants with the support conditions. That gives the familiar coefficients: 5/384 for a simply supported uniform load, 1/48 for a central point load, 1/3 and 1/8 for cantilevers, and 1/384 and 1/192 for fully fixed ends. The theory assumes a straight, prismatic beam of linear-elastic material, small deflections, and plane sections that stay plane; shear deformation is ignored, which is accurate for spans more than about ten times the depth.
Deflection depends on the product E I, the flexural stiffness. E is a material constant (about 200 GPa or 29,000 ksi for any structural steel, whatever its strength grade) and I depends only on the shape of the cross-section. That is why a higher-strength steel does nothing for deflection and why doubling a beam's depth cuts deflection by a factor of eight. Timber E values in the presets are mean values: EN 338 lists 11 GPa for C24 and 8 GPa for C16, and the NDS Supplement gives 1,600,000 psi for Douglas fir-larch No.2 and 1,400,000 psi for spruce-pine-fir No.2.
The limits come from the International Building Code, Table 1604.3: L/360 for floor live load, L/240 for floors under total load and for roofs with a plaster ceiling, and L/180 for roofs without a ceiling. Eurocode practice is similar, with L/250 for quasi-permanent load and L/300 or stricter where finishes can crack.
Common use cases
Sizing floor joists and beams
Check that a timber joist, steel beam or glulam meets L/360 under live load before ordering material.
Shelves, mezzanines and racks
Estimate how far a shelf or platform beam will sag with a known load so it looks and feels solid.
Cantilevered brackets and canopies
Get the tip deflection and slope of a bracket, sign arm or balcony beam under a point or uniform load.
Machine frames and test rigs
Keep aluminium or steel frame members stiff enough for alignment-sensitive equipment.
Checking hand calculations
Students and engineers can confirm a textbook answer and see the full deflected shape.
Tips and limitations
- Use the imposed (variable) load for this check: the UK National Annex says deflections due to permanent actions need not be included.
- Steel E in Eurocode 3 is 210 GPa; timber to EN 338 uses the mean E for the strength class (11 GPa for C24, 8 GPa for C16) and has its own limits in the timber Eurocode.
- For a cantilever the UK NA limit is length/180 measured on the cantilever length itself.
Sources and further reading
- Structure: Approved Document A, Ministry of Housing, Communities and Local Government. Statutory guidance on the structural requirements of the Building Regulations in England.
- Eurocode 3: Design of steel structures, European Commission Joint Research Centre. EN 1993-1-1 section 7 (serviceability); the limits themselves are set nationally, in the UK by the National Annex.
- Design codes and standards: serviceability limit state, SteelConstruction.info. UK NA to BS EN 1993-1-1 limits under variable actions only: cantilevers length/180, beams carrying plaster or brittle finish span/360, other beams span/200; different limits may be used with the client's agreement.
- Universal beams: dimensions and properties (Blue Book), Steel for Life and the Steel Construction Institute. 203 x 133 x 25 UB: Iy 2,340 cm⁴.
Frequently asked questions
What deflection limit applies to a steel beam in the UK?
The UK National Annex to BS EN 1993-1-1 suggests span/360 for beams carrying plaster or other brittle finishes, span/200 for other beams and length/180 for cantilevers, all under the variable load. They are recommendations, so the project specification can set tighter or looser values.
Is span/360 under total load or imposed load?
In the UK National Annex it is under the variable actions, which for most floor beams means the imposed load alone. Checking total load against span/360 is stricter than the annex asks for.
Why does this version use E = 210 GPa for steel?
BS EN 1993-1-1 takes the modulus of elasticity of structural steel as 210,000 N/mm². The US version uses 200 GPa, so the same beam shows about 5% less deflection here.
Where do I find I for a UB or UC?
The Blue Book tables published by Steel for Life and the SCI give Iy and Iz for every UK section. Use Iy for a beam bending about its strong axis; 203 x 133 x 25 UB is 2,340 cm⁴.
Do Building Regulations set beam deflection limits?
Not as numbers. Approved Document A sets out how the structural requirements of the Building Regulations can be met in England; the deflection limits themselves come from the design standard the engineer works to, here the Eurocode and its UK National Annex.
Is there an in-depth guide to the Beam Deflection Calculator?
Yes. “Beam Deflection Formulas: Where 5wL⁴/384EI Comes From and When L/360 Applies” covers the background, how it works, common pitfalls and worked examples. Read the full guide.
Related Tools You May Like
Free, in-browser tools that pair well with this one.