India version. Checks deflection against IS 800:2007 Table 6 and IS 456:2000 clause 23.2 instead of US IBC values, in kN, metres and mm with an ISMB 250 example. US version

Beam Deflection Calculator (IS 800, IS 456)

Deflection of steel or RCC beams checked against IS 800 Table 6 (span/300, span/360) and IS 456 (span/250, span/350), with ISMB sections, kN and mm.

The interactive tool loads here when JavaScript runs.

About this tool

What is the Beam Deflection Calculator?

Indian steel beams are checked for deflection under IS 800:2007 Table 6. For floors and roofs of ordinary buildings under live load, the limit is span/300 where the finishes are not susceptible to cracking and span/360 where they are, such as plastered or tiled ceilings; cantilevers get span/150 and span/180. Clause 5.6.1 calls these recommended limits, checked under service loads by elastic analysis, and allows greater or lesser values where the finishes or the client's intended use call for them. Amendment No. 1 (January 2012), printed in the public copy, replaces the clause's "load factor of 1.0" with "load factors of Table 4" and counts all post-construction loads, including superimposed dead loads, as live load for Table 6; apply the amendments in force. Set "Deflection limits from" to IS 800 / IS 456 and the check table shows these rows.

The default case is an ISMB 250 (Ixx 5,130 cm⁴ from IS 808:1989 Table 2.1) spanning 6 m with 12 kN/m of live load. It deflects 19.7 mm, span/304: inside span/300 at 99% of the limit, but over span/360 by 18%. Whether the beam is acceptable therefore depends on what it carries, which is exactly the decision Table 6 is built around.

For RCC members, IS 456 clause 23.2 limits the final deflection under all loads, including creep and shrinkage, to span/250, and the part after partitions and finishes are in place to span/350 or 20 mm, whichever is less. The calculator gives the elastic deflection for a given E and I; for concrete you still need the cracked section and long-term effects, or the span-to-depth ratios in 23.2.1.

  • Seven standard support and load cases, including an off-centre point load
  • Maximum deflection, its location, both end slopes, reactions and peak moment
  • Deflection limit checks with utilisation from IBC Table 1604.3, the UK NA to BS EN 1993-1-1, IS 800 / IS 456 or NBC Part 9, plus optional bending stress from S
  • Typical E presets for steel, stainless, aluminium, timber grades, glulam and concrete
  • SI and US units with conversion in place, deflected-shape chart, copy and share link
Read the guide: Beam Deflection Formulas: Where 5wL⁴/384EI Comes From and When L/360 Applies

Updated

How to use the Beam Deflection Calculator

  1. Choose SI or US units. The force unit can be kN or N, or kip or lbf; switching systems converts the numbers you already typed.
  2. Pick the support and load case. For an off-centre point load, enter its distance a from the left support.
  3. Enter the span and the load. For a uniform load include the beam's self-weight and any dead load, not only the live load.
  4. Pick a material to fill in a typical E, or type your own, then enter the second moment of area I about the bending axis. Add the section modulus S if you also want the bending stress.
  5. Read the maximum deflection, its position, the end slopes and the moment, then check the L/180, L/240 and L/360 table and the deflected-shape chart.

Worked examples

ISMB 250 floor beam, 6 m, live load 12 kN/m

Input

Simply supported, 6 m, UDL 12 kN/m, E 200 GPa, I 5,130 cm⁴, IS 800 / IS 456 limits

Output

19.7 mm (span/304); span/300 allows 20 mm (99%); span/360 allows 16.7 mm (118%, exceeds)

Acceptable under a metal deck ceiling, too flexible under plaster. ISMB 300 or a reduced span would pass both.

Same beam at 9 kN/m

Input

Simply supported, 6 m, UDL 9 kN/m, E 200 GPa, I 5,130 cm⁴

Output

14.8 mm (span/405); passes span/360 at 89%

Deflection is directly proportional to load, so a quarter less load gives a quarter less deflection.

Background and insight

All of these formulas come from integrating the Euler-Bernoulli beam equation, E I y'' = M(x), twice and fixing the constants with the support conditions. That gives the familiar coefficients: 5/384 for a simply supported uniform load, 1/48 for a central point load, 1/3 and 1/8 for cantilevers, and 1/384 and 1/192 for fully fixed ends. The theory assumes a straight, prismatic beam of linear-elastic material, small deflections, and plane sections that stay plane; shear deformation is ignored, which is accurate for spans more than about ten times the depth.

Deflection depends on the product E I, the flexural stiffness. E is a material constant (about 200 GPa or 29,000 ksi for any structural steel, whatever its strength grade) and I depends only on the shape of the cross-section. That is why a higher-strength steel does nothing for deflection and why doubling a beam's depth cuts deflection by a factor of eight. Timber E values in the presets are mean values: EN 338 lists 11 GPa for C24 and 8 GPa for C16, and the NDS Supplement gives 1,600,000 psi for Douglas fir-larch No.2 and 1,400,000 psi for spruce-pine-fir No.2.

The limits come from the International Building Code, Table 1604.3: L/360 for floor live load, L/240 for floors under total load and for roofs with a plaster ceiling, and L/180 for roofs without a ceiling. Eurocode practice is similar, with L/250 for quasi-permanent load and L/300 or stricter where finishes can crack.

Common use cases

  • Sizing floor joists and beams

    Check that a timber joist, steel beam or glulam meets L/360 under live load before ordering material.

  • Shelves, mezzanines and racks

    Estimate how far a shelf or platform beam will sag with a known load so it looks and feels solid.

  • Cantilevered brackets and canopies

    Get the tip deflection and slope of a bracket, sign arm or balcony beam under a point or uniform load.

  • Machine frames and test rigs

    Keep aluminium or steel frame members stiff enough for alignment-sensitive equipment.

  • Checking hand calculations

    Students and engineers can confirm a textbook answer and see the full deflected shape.

Tips and limitations

  • IS 800 uses E = 2 × 10⁵ N/mm² (200 GPa) for structural steel, which is the default here.
  • Use the unfactored (service) live load for the Table 6 check, not the factored load from the limit state design, and include finishes, partitions and other loads added after construction, as Amendment No. 1 asks.
  • Take I about the axis of bending: the major-axis value (Ixx in IS 808:1989) for an ISMB loaded in the usual way.

Sources and further reading

  1. IS 800:2007 General construction in steel, code of practice, Bureau of Indian Standards (public copy). Clause 5.6.1 (service loads), Table 6 deflection limits, and Amendment No. 1 (January 2012) printed before the title page.
  2. IS 808:1989 Dimensions for hot rolled steel beam, column, channel and angle sections, Bureau of Indian Standards (public copy). Table 2.1 medium weight beams: ISMB 250 second moment of area 5,130 cm⁴ about the major axis.
  3. IS 456:2000 Plain and reinforced concrete, code of practice, Bureau of Indian Standards (public copy). Clause 23.2, span/250 and span/350 or 20 mm.
  4. National Building Code of India, Bureau of Indian Standards. BIS page for the National Building Code of India (SP 7).

Frequently asked questions

What is the deflection limit for steel beams as per IS 800?

Table 6 of IS 800:2007 gives span/300 for floor and roof members whose finishes are not susceptible to cracking and span/360 where they are, both under live load. Cantilevers are limited to span/150 and span/180. Purlins, gantry girders and industrial buildings have their own rows.

What is the permissible deflection of an RCC beam as per IS 456?

Clause 23.2 limits the final deflection under all loads, including creep and shrinkage, to span/250, and the deflection after partitions and finishes are built to span/350 or 20 mm, whichever is less.

Should the IS 800 deflection check use factored loads?

No. Clause 5.6.1 says deflections are checked for the most adverse but realistic combination of service loads, by elastic analysis; Amendment No. 1 (2012) points it to the load factors of Table 4 rather than a flat 1.0, so apply the amendments in force. Table 6 gives recommended limits, and the clause allows greater or lesser values depending on whether the supported finishes can crack and on the client's intended use.

What is the moment of inertia of ISMB 250?

IS 808:1989 Table 2.1 gives 5,130 cm⁴ about the major axis (and 335 cm⁴ about the minor axis). Enter it with the cm⁴ unit; for other sections take the value from the same table.

How do I calculate deflection of a simply supported beam with a UDL?

δ = 5wL⁴ / (384EI). With w = 12 kN/m, L = 6 m, E = 200 GPa and I = 5,130 cm⁴ that is 19.7 mm. The calculator shows the same working in N and m.

Is there an in-depth guide to the Beam Deflection Calculator?

Yes. “Beam Deflection Formulas: Where 5wL⁴/384EI Comes From and When L/360 Applies” covers the background, how it works, common pitfalls and worked examples. Read the full guide.