South Africa version. Litres and °C, a 150 L geyser with a 3 kW element, Eskom's 60 °C geyser advice and costs in rand at the Homelight 60A rate from 1 April 2026, or your own c/kWh. US version

Geyser Heating Time and Cost Calculator (South Africa)

How long a 150 or 200 litre geyser takes to heat to 60 °C with a 3 or 4 kW element, and what each heat-up costs in rand at Eskom Homelight or your c/kWh rate.

The interactive tool loads here when JavaScript runs.

About this tool

What is the Water Heating Time Calculator?

In a South African home the electric geyser is usually the biggest single user of electricity: Eskom says it can account for up to 50% of a household's use. This version answers the two questions people ask about it, how long it takes to heat a full geyser and what that costs in rand. It opens on a 150 litre geyser heated from 15 °C to 60 °C by a 3 kW element: 7.84 kWh goes into the water, it takes about 2 hours 40 minutes and costs R 27,49 at the Homelight 60A rate.

The 60 °C target follows Eskom's advice to check that your geyser temperature is set no higher than 60 °C, and to fit a geyser blanket on older units and insulate the exposed hot water pipes. Every degree above that costs energy: the same geyser heated to 70 °C takes about 36 minutes longer and costs R 6,11 more per heat-up.

Prices depend on who supplies you. Eskom's direct Homelight customers pay a single energy rate with no fixed charge, from 1 April 2026 to 31 March 2027: 270.30 c/kWh on Homelight 20A and 343.61 c/kWh on Homelight 60A, both including VAT. Municipal customers pay their council's tariff. Enter your rate in rand per kWh from your prepaid slip or bill. Eskom writes cents per kWh with a decimal point and the price field needs a decimal point too, so 343.61 c/kWh goes in as 3.4361; the cost comes back in rand the way this page writes it, as in R 27,49.

  • Electric heaters in kW or gas and oil burners in BTU/h
  • Heat-up time, energy in the water and energy purchased
  • Cost per heat-up per kWh or per therm in a choice of currencies
  • Recovery rate in gal/h or L/h at the chosen temperature rise
  • Comparison table across common heater ratings
Read the guide: How Long Does It Take to Heat Water? Tanks, Kettles and Recovery Rate

Updated

How to use the Water Heating Time Calculator

  1. Enter the geyser size in litres from its rating plate and the element rating in kW.
  2. Enter the cold water temperature and 60 °C as the target (lower in winter, when the cold water is colder).
  3. Keep the efficiency at about 98%: an element sitting in the water puts almost all of its power into it.
  4. Enter your electricity price in rand per kWh (divide c/kWh by 100) to see the cost per heat-up.

Worked examples

150 L geyser, 3 kW element, Homelight 60A

Input

150 L, 15 → 60 °C, 3 kW, 98%, 3.4361 rand per kWh

Output

2 h 40 min, 7.84 kWh into the water, 8.00 kWh bought, R 27,49

On Homelight 20A at 270.30 c/kWh the same heat-up costs R 21,63. Eskom describes the 20A supply as one where all appliances running together should stay under about 4 400 W, so a 3 kW element and a 2.2 kW kettle at the same time would already be too much.

200 L geyser with a 4 kW element

Input

200 L, 15 → 60 °C, 4 kW, 98%, 3.4361 rand per kWh

Output

2 h 40 min, 10.67 kWh bought, R 36,66

A bigger element on a bigger geyser gives the same heat-up time for a third more energy. The 4 kW element draws about 17 A at 230 V, well within the roughly 13 200 W Eskom gives for a 60A Homelight supply.

Reheating after a seven-minute shower

Input

70 L, 15 → 60 °C, 3 kW, 98%, 3.4361 rand per kWh

Output

1 h 14 min, 3.73 kWh bought, R 12,83

Eskom suggests showers of about seven minutes with a showerhead that flows at less than 10 litres a minute, which uses at most about 70 litres. If all of that came from the geyser, replacing it with cold water and reheating costs R 12,83; mixed with cold at the tap, the geyser's share is less.

Background and insight

The physics is the sensible heat equation, Q = m·c·ΔT, with the mass taken from the volume at the starting temperature. The calculator uses water density from the Kell equation, about 0.999 kg per litre at cold-water temperatures, and a specific heat of 4,186 J/kg·K. In US units this is the familiar plumbing rule: 8.34 lb per gallon times 1 BTU per lb per °F, so a 50 gallon tank needs about 417 BTU for every degree Fahrenheit.

Efficiency is where electric and gas heaters differ. An immersed electric element turns essentially all of its power into heat in the water; the 2% default allows for wiring and a little loss through the tank wall during heating. Gas burners lose heat up the flue, so the recovery efficiency on the rating plate of a residential gas tank is typically 76 to 82%, and condensing units reach above 90%. Kettles lose some heat from their body and lid and are often closer to 80 to 90%.

Recovery rate is how US manufacturers rate tank heaters: the gallons per hour they can heat through a given rise, often 90 °F. It equals the delivered BTU/h divided by 8.34 times the rise. Standby losses, scale on elements, cold water mixing during draws and stratification in the tank all make real heat-up times a little longer than this ideal figure.

Common use cases

  • Choosing a water heater

    Compare element sizes or gas inputs for how quickly a tank recovers after a run of showers.

  • Off-grid and solar diversion

    Estimate how much of a day a 1.5 or 3 kW immersion heater needs to heat a cylinder from surplus solar power.

  • Running cost per heat-up

    Put a price on a full tank of hot water for electric resistance versus gas at local tariffs.

  • Process and lab water

    Work out the warm-up time for a wash tank, a bath or a boiler loop with a known heater rating.

Tips and limitations

  • A geyser timer lets you choose when it heats; Eskom's tips are to insulate the geyser and the first 1.5 m of pipes.
  • In winter the cold water entering the geyser is colder, so a full heat-up takes longer. From 10 °C the 150 L geyser takes 2 h 57 min and costs R 30,57.
  • Standing heat loss through the geyser walls and pipes is not included here; a geyser blanket on an older unit, as Eskom advises, cuts that loss.
  • This calculator models a resistance element. For a heat pump water heater, divide the kWh shown by the unit's COP (for example 3) for a rough energy figure; its heating time depends on its rated heat output, not its electrical input.

Sources and further reading

  1. Tariffs and Charges Booklet 2026/2027, Eskom. Homelight 20A 270.30 c/kWh and Homelight 60A 343.61 c/kWh including VAT, non-local authority charges 1 April 2026 to 31 March 2027; approximate maximum of 4 400 W on 20A and 13 200 W on 60A supplies.
  2. Energy-wise ways to get ready for winter, Eskom. Geyser can use up to 50% of household electricity; set it no higher than 60 °C; geyser blanket and pipe insulation.
  3. Energy saving tips, Eskom. Insulate the geyser and the first 1.5 metres of pipes.
  4. Use electricity smartly: bathrooms, Eskom. Seven-minute showers; showerheads under 10 litres per minute.
  5. University Physics Volume 2, 1.4: Heat Transfer, Specific Heat, and Calorimetry, OpenStax. Q = mcΔT.

Frequently asked questions

How long does a geyser take to heat up?

A 150 L geyser with a 3 kW element takes about 2 hours 40 minutes from 15 °C to 60 °C, and a 200 L geyser with a 4 kW element takes about the same. From colder winter water it takes longer: about 2 hours 57 minutes for the 150 L geyser from 10 °C.

How much does it cost to heat a geyser in South Africa?

A full 150 L heat-up from 15 °C to 60 °C buys about 8.0 kWh: R 27,49 at Eskom's Homelight 60A rate of 343.61 c/kWh and R 21,63 on Homelight 20A at 270.30 c/kWh, both from 1 April 2026 including VAT. Municipal tariffs differ, so use the rate on your own slip or bill.

What temperature should I set my geyser to?

Eskom advises setting the geyser temperature no higher than 60 °C. Heating the 150 L geyser to 70 °C instead takes about 36 minutes more and costs R 6,11 more each time at the Homelight 60A rate.

Should I switch my geyser off during the day?

A geyser timer lets you choose when the geyser heats. This calculator gives the time and cost of each heat-up; it does not model the heat a geyser loses while it stands hot, which is what switching it off saves. Eskom's tips are to insulate the geyser and the first 1.5 m of pipes, which cuts that standing loss whether or not you use a timer.

Can I run a geyser on a 20A Homelight supply?

Yes, but not with much else at the same time. Eskom says appliances on a 20A limited supply should not exceed about 4 400 W together, so a 3 kW element leaves only 1 400 W for everything else while it is heating. The 60A supply allows about 13 200 W.

How many units does a geyser use?

One unit is one kWh. A full heat-up of a 150 L geyser from 15 °C to 60 °C uses about 8 units, and reheating 70 litres after a shower about 3.7 units. Divide your prepaid purchase in rand by your c/kWh rate in rand to see how many units it buys.

Is there an in-depth guide to the Water Heating Time Calculator?

Yes. “How Long Does It Take to Heat Water? Tanks, Kettles and Recovery Rate” covers the background, how it works, common pitfalls and worked examples. Read the full guide.