New Zealand version. Set up for New Zealand linings: GIB plasterboard in 1200 mm widths and 2400 to 6000 mm lengths, rooms in metres and a weight check from the GIB Site Guide. US version

GIB Board Calculator (Plasterboard, New Zealand)

How many sheets of GIB plasterboard a room needs in 1200 mm wide sheets from 2400 to 6000 mm long, less doors and windows, with board weight in kg.

The interactive tool loads here when JavaScript runs.

About this tool

What is the Drywall Calculator?

GIB is the plasterboard made by Winstone Wallboards in New Zealand, and its Site Guide lists GIB Standard in 10 mm and 13 mm thicknesses, 1200 mm wide, in lengths from 2400 to 6000 mm, plus the 1350 mm wide GIB Wideline for horizontal fixing on walls taller than 2.4 m. This version opens with those metric sheets and a bedroom measured in metres.

A 3.4 x 3.0 m bedroom with a 2.4 m stud, one 810 x 1980 mm door and a 1200 x 1200 mm window has 37.88 m² to line, walls and ceiling together. That is 15 sheets of 2400, 10 sheets of 3600 or 8 sheets of 4800, with 10% added. The guide tells fixers to minimise joints by using the largest sheet size available, and says wall sheets usually end up fixed horizontally for that reason.

Long sheets are heavy. The guide gives 10 mm GIB Standard at no more than 7.0 kg per m² and 13 mm at 9.0 kg, so the 43.2 m² of 10 mm board for the bedroom weighs up to about 302 kg, and a single 1200 x 6000 sheet up to about 50 kg. Plan the handling and a clear path into the room before choosing the longest sheets.

  • Walls, ceiling, openings, extra area and multiple identical rooms
  • Sheet sizes from 4x8 to 54 in x 12 ft and 1200 x 2400 to 3000 mm
  • Editable screw, tape and compound rates with pails and rolls
  • Board cost, imperial and metric with feet-inch input
  • Copy results and share a link with your inputs
Read the guide: How Much Drywall, Mud and Tape? Estimating a Room

Updated

How to use the Drywall Calculator

  1. Keep the units on metric and enter the room length, width and stud height in metres.
  2. Enter door and window sizes in millimetres, and tick the ceiling if it is being lined.
  3. Pick the sheet length your fixer will hang. Longer sheets fixed horizontally mean fewer butt joints.
  4. Replace the screw, tape and compound rates with the figures for the GIB system and compounds you are using.

Worked examples

Bedroom in 2400 mm sheets

Input

3.4 x 3.0 m, 2.4 m stud, ceiling lined, one 810 x 1980 mm door, one 1200 x 1200 mm window, 1200 x 2400 sheets, 10% extra

Output

37.88 m² net (30.72 m² of walls, 10.20 m² of ceiling); 15 sheets (14.47 exact); 43.20 m² of board

At the 7.0 kg per m² maximum for 10 mm GIB Standard, the 15 sheets weigh up to about 302 kg in total, or about 20 kg each.

The same bedroom in 4800 mm sheets

Input

As above, 1200 x 4800 sheets

Output

8 sheets (7.23 exact); 46.08 m² of board

A 4.8 m sheet runs past both 3.4 m and 3.0 m walls, so each wall takes two horizontal sheets and an offcut, and there are no butt joints in the middle of a wall. The extra 2.88 m² of board is the price of fewer joints.

Lounge walls with a 2.7 m stud

Input

6.0 x 4.5 m, 2.7 m stud, walls only, two 810 x 1980 mm doors, one 2400 x 1500 mm window, 1200 x 2700 sheets, 10% extra

Output

49.89 m² net; 17 sheets (16.94 exact); 55.08 m² of board

For a 2.7 m stud fixed horizontally, the 1350 mm GIB Wideline covers the height in two sheets. The calculator only lists 1200 mm widths, so divide the net area by the Wideline sheet area (3.24 m² for 1350 x 2400) to check that option.

Background and insight

Wall area is the room perimeter times the height; the ceiling is length times width. Openings come off the total, and a waste allowance of 10 to 15% covers cut-offs at doors, windows and corners. Longer sheets reduce the number of butt joints, which are the hardest to finish, so a 12 ft room is often hung with 12 ft sheets even though the sheet count barely changes.

For finishing materials the calculator uses typical rates and labels them as such: about 32 screws per 4x8 sheet (one per square foot, from screws at 12 in centres on ceilings and 16 in on walls per GA-216 and the board makers' instructions), about 370 ft of paper tape per 1,000 square feet of board (USG's published coverage), and about 9.4 gallons of ready-mixed all-purpose compound per 1,000 square feet for taping and three coats. Lightweight and setting compounds cover differently, so edit the rate to suit.

Common use cases

  • Ordering board for a renovation

    Count sheets per room and add rooms of the same size before calling the supplier.

  • Basement finishing

    Estimate walls only, with tall or short sheets, for a basement with exposed or dropped ceilings.

  • Planning finishing labour

    Use tape and compound quantities to plan coats and buckets for a taping crew.

  • Comparing sheet sizes

    See how 4x8, 4x12 and 54 in sheets change the count and the number of joints.

Tips and limitations

  • Check the framing before lining: the GIB Site Guide asks for timber moisture content of 18% or less at the time of fixing.
  • Where horizontally fixed sheets leave edge joints unsupported, the guide says stud centres must not exceed 600 mm.
  • Keep GIB dry, stacked off the ground and under cover until it is fixed, and order wall and ceiling sheets in separate stacks.
  • GIB setting compounds come as powder in kg bags and the air-drying ready-mix in 10 or 15 L pails. The compound line here is ready-mix in litres, so use the coverage printed on your product.

Sources and further reading

  1. GIB Site Guide, Winstone Wallboards. Board range, sheet coverage table, maximum kg per m², joint placement, 600 mm stud centres for horizontal fixing and 18% timber moisture.
  2. GIB Wet Area Systems specification and installation manual, Winstone Wallboards. Water-resistant core boards and Building Code clause E3 requirements for wet areas.

Frequently asked questions

How many sheets of GIB do I need for a bedroom?

Add the wall and ceiling areas, take off the door and windows, add about 10% and divide by the sheet area: 2.88 m² for 1200 x 2400, 4.32 m² for 1200 x 3600, 5.76 m² for 1200 x 4800. A 3.4 x 3.0 m bedroom with a 2.4 m stud takes 15, 10 or 8 sheets.

What sizes does GIB plasterboard come in?

The GIB Site Guide coverage table lists 1200 mm wide sheets in 2400, 2450, 2700, 2750, 3000, 3300, 3600, 4200, 4800 and 6000 mm lengths, and 1350 mm Wideline in 2400, 3600, 4800 and 6000 mm. Not every board type comes in every size, so check the range table for your board.

Should GIB be fixed horizontally or vertically?

The guide says wall sheets must be set out to minimise joints, which usually means fixing them horizontally, and recommends using the largest sheet size available. With horizontal fixing, unsupported sheet edge joints are allowed as long as stud centres do not exceed 600 mm.

How heavy is a sheet of GIB board?

The guide gives a maximum of 7.0 kg per m² for 10 mm GIB Standard and 9.0 kg per m² for 13 mm. A 10 mm 1200 x 2400 sheet is therefore up to about 20 kg, and a 1200 x 6000 sheet up to about 50 kg.

What GIB do I use in a bathroom or laundry?

GIB Aqualine has a water-resistant core designed for wet areas. The GIB Wet Area Systems manual notes that the Building Code does not itself call for water-resistant linings, but clause E3 requires surfaces next to sanitary fixtures to be impervious and easily cleaned and splash not to get behind linings.

Does the calculator cover 1350 mm GIB Wideline?

Not directly: its sheet list is 1200 mm wide. To size Wideline, take the net area from the calculator, add your waste allowance and divide by 3.24 m² (1350 x 2400), 4.86 m² (1350 x 3600) or 6.48 m² (1350 x 4800).

Is there an in-depth guide to the Drywall Calculator?

Yes. “How Much Drywall, Mud and Tape? Estimating a Room” covers the background, how it works, common pitfalls and worked examples. Read the full guide.