South Africa version. Running cost in rand at Eskom's Landrate and Homelight energy prices from 1 April 2026, with flow in L/s, head in metres and the motor in kW. US version

Pump Power and Running Cost Calculator (South Africa)

Size a borehole, booster or irrigation pump in kW from flow and head, pick the motor, and cost the running hours in rand at Eskom Landrate or Homelight prices.

The interactive tool loads here when JavaScript runs.

About this tool

What is the Pump Power Calculator?

The pumps most often sized in South Africa are borehole pumps, pressure boosters and farm irrigation pumps, and after "what kW motor?" the next question is what the pump will cost in rand. This version opens on a borehole pump delivering 1.5 L/s (5.4 m³/h) against 60 m of total head, with a 55% efficient pump and an 80% efficient motor. The shaft needs 1.60 kW, so the next IEC motor size is 2.2 kW; the motor draws 2.00 kW, and 1 500 hours a year uses 3 003 kWh, about R 10 722 at the Landrate price below.

That price comes from Eskom's tariff booklet for 1 April 2026 to 31 March 2027. Landrate is the tariff for rural customers with a supply of up to 100 kVA below 500 V. On Landrate 1, 2 and 3 three charges are billed per kWh: the energy charge of 279.34 c, the ancillary service charge of 0.52 c and the network demand charge of 77.12 c, all including VAT. Together that is 356.98 c/kWh. Eskom's booklet writes cents per kWh with a decimal point, and the price field needs a decimal point too, so that goes in as 3.5698 rand per kWh; rand amounts on this page are written the way the calculator shows them. The daily charges are separate: on Landrate 1 the network capacity charge is R 77,80, the service and administration charge R 30,65 and the generation capacity charge R 4,73 per day, including VAT. That is R 113,18 a day whether or not the pump runs, so leave it out of the price per kWh.

Urban homes supplied directly by Eskom on Homelight 60A pay a single 343.61 c/kWh including VAT, with no daily charge, so the calculator's cost is the whole bill for the pump. Municipal customers pay their council's own tariff; take the c/kWh figure from your bill or prepaid slip.

  • Hydraulic, shaft and electrical power in kW and hp
  • Head or pressure-rise input with density-based conversion
  • Next standard IEC (kW) and NEMA (hp) motor size
  • Yearly energy and running cost in your currency
  • NPSH available with water vapour pressure from 0 to 100 °C
Read the guide: Pump Power, Head and Efficiency: From ρgQH to the Electricity Bill

Updated

How to use the Pump Power Calculator

  1. Enter the flow in L/s or m³/h. A borehole yield test or the pump's duty point gives this figure.
  2. Enter the total head in metres: the pumping water level below the surface, plus the height to the top of the tank, plus pipe friction.
  3. Take the pump and motor efficiencies from the maker's curve and rating plate at your duty point.
  4. Set the hours per year, choose R as the currency and enter your price per kWh in rand (divide c/kWh by 100).

Worked examples

Farm borehole on Landrate 1

Input

1.5 L/s, total head 60 m, pump 55%, motor 80%, 1 500 h a year at 3.5698 rand per kWh

Output

Water power 0.88 kW, shaft 1.60 kW, next IEC motor 2.2 kW; 2.00 kW drawn; 3 003 kWh, about R 10 722 a year

This covers the per-kWh charges only. The Landrate 1 daily charges of R 113,18 come to about R 41 311 over a year, paid on the supply whatever the pump uses.

Pressure booster on Homelight 60A

Input

0.5 L/s, head 25 m, pump 40%, motor 75%, 500 h a year at 3.4361 rand per kWh

Output

Shaft 0.31 kW, next IEC motor 0.37 kW; 0.41 kW drawn; 204 kWh, about R 701 a year

Homelight has no daily charge, so this is the full cost of the booster. Eskom's booklet allows roughly 13 200 W of appliances running at once on a 60A supply, and the booster takes about 400 W of that.

Irrigation pump, 10 L/s at 40 m

Input

10 L/s, head 40 m, pump 70%, motor 90%, 2 000 h a year at 3.5698 rand per kWh

Output

Shaft 5.59 kW, next IEC motor 7.5 kW; 6.22 kW drawn; 12 430 kWh, about R 44 374 a year

The pump loses 1.68 kW between the shaft and the water and the motor another 0.62 kW. A pump chosen to run near its best efficiency point at the duty saves more here than a better motor does.

Background and insight

Hydraulic power is the rate of work done on the liquid: weight flow times head, P = ρgQH. In US units the same thing becomes water horsepower = gpm × ft × SG / 3960, the 3960 coming from 33,000 ft·lbf/min per hp divided by 8.33 lb per gallon. One mechanical horsepower is 745.7 W.

Pump efficiency comes from the manufacturer's curve at your duty point. Small end-suction pumps may reach 50 to 70% and large well-matched pumps 80 to 90%. Motor efficiency classes are set by IEC 60034-30-1, with IE3 (premium) motors roughly 85 to 96% depending on size. Standard motor ratings follow IEC 60072 in kW and NEMA MG 1 in hp.

Net positive suction head is about cavitation. NPSHa = (p_surface − p_vapour)/(ρg) + static suction head − suction losses. Hot water has a much higher vapour pressure (47.4 kPa at 80 °C versus 2.3 kPa at 20 °C), so a suction lift that works for cold water can starve a pump on hot water. Hydraulic Institute guidance (ANSI/HI 9.6.1) recommends an NPSH margin above NPSHr that depends on the application.

Common use cases

  • Motor sizing

    Get the shaft power and the next standard IEC or NEMA motor rating for a pump duty.

  • Energy audits

    Estimate yearly kWh and cost for an existing pump, and the saving from a more efficient pump or motor.

  • Cavitation checks

    Work out NPSH available on a lift or with hot water before choosing a pump.

  • Turning pressure into head

    Convert a gauge differential into metres or feet of head for a given liquid density.

Tips and limitations

  • Measure the head from the pumping water level during a yield test, not the rest level: water in a borehole drops while the pump runs.
  • Pick the next IEC size above the shaft power once; adding a margin on top of an already rounded-up motor wastes money on every kWh.
  • Landrate 4 has a higher energy charge, 458.64 c/kWh including VAT, but lower daily charges and no service charge, so check which Landrate your account is on.
  • If the pump runs off a solar array or a generator during outages, use the cost of that energy instead of the Eskom price.

Sources and further reading

  1. Tariffs and Charges Booklet 2026/2027, Eskom. Landrate charges and supply sizes; Homelight 20A and 60A energy charges and supply capacity; non-local authority charges effective 1 April 2026 to 31 March 2027.
  2. Schedule of standard prices for Eskom tariffs, 1 April 2026 to 31 March 2027, Eskom. The official tariff schedule: how energy, network and daily charges are structured for each tariff.
  3. IEC 60034-30-1: Efficiency classes of line operated AC motors (IE code), International Electrotechnical Commission. Motor efficiency classes and rated outputs in kW.

Frequently asked questions

What does electricity cost for a farm borehole pump?

For an Eskom rural supply on Landrate 1, 2 or 3, the per-kWh charges from 1 April 2026 are 356.98 c/kWh including VAT (energy 279.34 c, ancillary service 0.52 c and network demand 77.12 c). Multiply by the kWh the calculator shows. Daily charges are billed on top.

Should I add Eskom's daily charges to the price per kWh?

No. Network capacity, service and administration, and generation capacity charges are billed per point of delivery per day, whether the pump runs or not. On Landrate 1 they total R 113,18 a day including VAT. Add them separately if the pump is the only load on that supply.

How do Landrate 1 and Landrate 4 differ?

Landrate 4 is a single-phase 16 kVA supply. Its energy charge is 458.64 c/kWh including VAT against 279.34 c on Landrate 1, with the same ancillary and network demand charges, so each kWh costs 536.28 c in total. Its daily charges are lower: R 57,43 network capacity and R 3,11 generation capacity.

Can I run a booster pump on a Homelight 60A supply?

Yes, within the supply's capacity. Eskom's booklet says appliances running together should not exceed about 13 200 W on a 60A Homelight supply and about 4 400 W on 20A. Homelight 60A costs 343.61 c/kWh including VAT with no daily charge.

What size motor do I need for my borehole pump?

The next standard IEC size above the shaft power. For 1.5 L/s at 60 m with a 55% pump the shaft needs 1.60 kW, so a 2.2 kW motor. Borehole pumps come as matched pump and motor sets, so check the maker's curve for the exact model at your flow and head.

Do these prices apply if my municipality supplies my electricity?

No. The booklet prices are for Eskom's direct (non-local authority) customers. Municipal customers pay the tariff their council sets, so enter the c/kWh rate from your own bill.

Is there an in-depth guide to the Pump Power Calculator?

Yes. “Pump Power, Head and Efficiency: From ρgQH to the Electricity Bill” covers the background, how it works, common pitfalls and worked examples. Read the full guide.