Canada version. Feet and inches as Canadian lumber yards sell decking, 5/4x6 or 2x6 boards, 2x8 joists at 16 in, prices in C$ and a pointer to permits and guards. US version

Deck Calculator (Canada)

Count 5/4x6 or 2x6 deck boards, joists, beams, posts and screws for a Canadian deck in feet, priced in C$, with notes on permits, guards and frost footings.

The interactive tool loads here when JavaScript runs.

About this tool

What is the Deck Calculator?

Canadian decks are built from pressure-treated or cedar lumber sold in feet: 5/4x6 or 2x6 decking in 8 to 16 ft lengths over 2x8 or 2x10 joists at 16 in on centre. This version starts with a 16 x 12 ft deck on a ledger, boards running parallel to the house, priced in Canadian dollars.

Freestanding decks are common where a ledger would cut through the building envelope or where the house has brick veneer. Switch off the ledger, add a second beam near the house, and the calculator drops the joist hangers and counts the extra beam and posts.

Deck permits are set by your municipality under the provincial building code, often based on the height above ground, the area and whether the deck is attached. Guards, stairs and footings below the frost line are part of the permit review, so check with your building department before ordering.

  • Rows and boards by stock length, with nesting of short rows
  • Straight or diagonal decking and adjustable waste
  • Joists, rim, ledger, beam plies, posts and hangers
  • Face screws or hidden clips per crossing, with boxes and rate per area
  • Cut list, joist span readout, decking cost, metric and imperial
Read the guide: Estimating a Deck: Boards, Joists, Screws and Span Tables

Updated

How to use the Deck Calculator

  1. Choose imperial or metric and enter the deck length along the house and the projection out from it.
  2. Enter the actual board width, the gap between boards and the board length you will buy, then choose straight or diagonal boards.
  3. Set the joist spacing, joist size label and stock length, the rim thickness, and whether a ledger attaches the deck to the house.
  4. Enter the beams, plies, posts and the joist cantilever past the beam from your design or permit drawing.
  5. Choose face screws or hidden clips, the count per box and the waste, then read the materials and cut list.

Worked examples

16 x 12 ft deck on a ledger in 5/4x6

Input

5-1/2 in boards, 3/16 in gaps, 16 ft lengths, 2x8 joists at 16 in, one 2-ply beam on 3 posts, 18 in cantilever, 10% extra, C$25 a board

Output

26 rows, 29 boards (416 lf net); 13 joists at 11 ft 10-1/2 in; 676 screws (2 boxes of 350); 13 hangers; C$725 of boards

The joist span from ledger to beam is 10 ft 6 in; check it against the deck joist span table for your species and grade.

Freestanding 12 x 10 ft deck in 2x6

Input

2x6 boards (5-1/2 in) with 1/8 in gaps, 12 ft lengths, joists at 16 in, two 2-ply beams on 3 posts each, no ledger, C$18 a board

Output

22 rows, 25 boards; 10 joists; 6 posts; 440 screws; no hangers; C$450 of boards

Two beams carry the joists at both ends, so each needs its own footings below frost depth.

The 16 x 12 ft deck with diagonal boards

Input

Boards at 45 degrees, joists at 12 in, 15% extra

Output

30 boards; 17 joists; 574 screws; C$750 of boards

Diagonal boards need closer joists and more waste, which adds four joists and a board over the straight layout.

Background and insight

Joists are counted like studs: ceil(length / spacing) + 1 including both end joists. Rows of decking are ceil(projection / (board width + gap)), using the actual width. A 5/4x6 board is 5-1/2 in wide, so with a 3/16 in gap each row covers 5-11/16 in. When the deck is shorter than the boards, rows nest two or more to a board; when it is longer, butt joints have to land on joists and each row takes more than one board. Two face screws per board at every joist is the standard pattern, a little over 3 screws per square foot for 5-1/2 in boards at 16 in, and hidden clips use one per crossing.

Joist sizes and spans are a code question. In the US, IRC Section R507 holds the deck joist and deck beam span tables, which depend on species, grade, spacing and cantilever, and the American Wood Council publishes the same rules as DCA 6. Composite decking makers often require 12 in joist spacing for diagonal boards. The calculator shows your joist span so you can compare it with the table, but it does not size members.

Common use cases

  • Pricing a deck before a permit

    Get board, joist and fastener counts to compare composite and timber quotes.

  • Planning a resurface

    Count new boards and screws for existing framing by entering the deck size and joist spacing.

  • Choosing board direction

    Compare straight and diagonal layouts for board count, waste and fasteners.

  • Ordering stock lengths

    Try 12, 16 and 20 ft boards to find the length that nests best with your deck size.

Tips and limitations

  • Use fasteners and hangers rated for treated lumber; the copper-based treatments corrode plain steel.
  • Footings must bear below the frost line in most of Canada; ask your municipality for the local depth.
  • Leave 1/8 to 1/4 in between boards for drainage once wet treated boards have shrunk, and gap the boards from the house wall.

Sources and further reading

  1. National Building Code of Canada 2025, National Research Council Canada (Government of Canada Publications). Part 9 covers wood-frame construction, guards and footings for houses.
  2. Lumber, Canadian Wood Council. Canadian dimension lumber sizes and grades.
  3. Prescriptive Residential Wood Deck Construction Guide (DCA 6), American Wood Council. A US guide; Canadian decks follow the provincial code and the municipality.

Frequently asked questions

Do I need a permit to build a deck in Canada?

It depends on the municipality. Many require a permit for any deck attached to the house, or for decks above a set height above grade or over a set area, and the threshold differs between cities and provinces. Check your city's building department before you start.

Should I use 5/4x6 or 2x6 decking?

5/4x6 (about 1 in thick) is lighter and cheaper and is common on 16 in joists. 2x6 (1-1/2 in thick) is stiffer and suits wider joist spacing or heavy traffic. Both are 5-1/2 in wide, so the board count is the same; the joist spacing allowed differs.

How many deck boards do I need for a 16 x 12 deck?

With 5-1/2 in boards and 3/16 in gaps, the 12 ft projection takes 26 rows. With 16 ft boards each row is one board, so 26 plus 10% is 29 boards.

How deep do deck footings need to go in Canada?

Below the frost line for your area, which varies widely across the country. The building department or the provincial code sets the depth; some freestanding low decks can sit on surface footings where the municipality allows them.

Does my deck need a guard?

Guards are required where the deck surface is high enough above the ground that a fall is a hazard, with height and opening limits set by Part 9 of the National Building Code as adopted by your province. Size them with the permit drawings.

Is there an in-depth guide to the Deck Calculator?

Yes. “Estimating a Deck: Boards, Joists, Screws and Span Tables” covers the background, how it works, common pitfalls and worked examples. Read the full guide.