Canada version. Asphalt shingles in squares and bundles as Canadian roofers order them, CA$ prices, and NBC Section 9.26 rules on minimum slope and ice-dam eave protection. US version
Roofing Shingle Calculator (Canada)
Roof area, squares and shingle bundles from your footprint and pitch, with ridge cap and underlay, plus National Building Code slope and eave protection rules.
The interactive tool loads here when JavaScript runs.
About this toolWhat is the Roofing Calculator?
Most Canadian houses are roofed with asphalt shingles sold in bundles, three to a square of 100 sq ft for most products. This version keeps that method and adds what the National Building Code of Canada changes: the slopes shingles are allowed on and the eave protection that keeps ice dams from forcing water under them.
Normal shingle application needs a slope of at least 1 in 3 (4/12). Between 1 in 6 and 1 in 3 the code allows a low-slope application with its own underlay and lapping rules in Subsection 9.26.8, and below 1 in 6 you need a membrane or other low-slope roofing.
Eave protection must run from the roof edge at least 900 mm up the slope to 300 mm inside the inner face of the exterior wall. It is not required on unheated garages and carports, on roofs of 1 in 1.5 (8/12) or steeper, or in regions with 3,500 or fewer degree-days, which applies only to the mildest locations, such as parts of coastal British Columbia.
- Gable, hip and shed roofs from footprint, overhang and pitch
- Pitch as rise in 12 or degrees, with a multiplier table
- Squares, bundles, underlayment rolls, ridge cap and drip edge in one result
- Editable bundles per square, roll coverage, cap coverage and piece length
- Imperial or metric inputs, cost per bundle, copy and share
Updated
How to use the Roofing Calculator
- Enter the building footprint in feet and the overhang on each side.
- Enter the pitch as rise in 12, or switch to degrees.
- Set bundles per square from the wrapper; heavy laminated shingles can need more than three.
- Add waste: about 10% for a gable, 15% for hips and valleys.
Worked examples
Two-storey house with a 6/12 gable roof
Input
40 x 30 ft footprint, 1 ft overhang, 6/12, gable, 10% waste, 3 bundles per square
Output
1,503 sq ft (139.6 m²); 15.03 squares; 50 bundles; 5 rolls of #15 felt; 2 ridge cap bundles
At 6/12 (1 in 2) the roof is above the 1 in 3 minimum and below 1 in 1.5, so eave protection is needed in most of Canada.
The same footprint as a hip roof
Input
40 x 30 ft, 1 ft overhang, 6/12, hip, 15% waste
Output
1,503 sq ft; 52 bundles; 5 ridge cap bundles
Same surface area, more cutting waste and far more ridge cap for the four hips. Eave protection runs along all four sides.
Detached garage at 3/12
Input
24 x 24 ft, 1 ft overhang, 3/12, gable, 10% waste
Output
697 sq ft; 6.97 squares; 23 bundles
A 3/12 roof is 1 in 4: shingles are allowed only as a low-slope application under NBC 9.26.8. An unheated garage does not need eave protection.
Background and insight
The pitch multiplier is the length of a rafter per unit of horizontal run: the square root of 1 + (rise / 12)². At 6 in 12 it is 1.118, so a roof covers 11.8% more surface than its footprint; at 12 in 12 (45°) it is 1.414. Because every plane of a simple gable or hip roof has the same pitch, multiplying the total plan area by this one factor gives the whole roof area, however the planes are arranged.
Asphalt shingles are sold so that three bundles cover one square for most three-tab and many architectural products, but heavier laminated shingles can need four or five, which is why the wrapper is the final word. Nominal underlayment coverage is about 400 ft² for a roll of #15 felt, 200 ft² for #30 and around 1,000 ft² for many synthetic rolls, less once laps are taken out.
Hips and valleys need cut shingles along their full length, and dormers add both. A plain gable is often estimated at 10% waste and a cut-up hip roof at 15% or more, which is a judgment call rather than a formula.
Common use cases
Checking a reroof quote
Compare the number of squares on a contractor quote with an independent figure from the footprint and pitch.
Ordering shingles for a shed or garage
Get bundles, underlayment and drip edge for a small DIY roof in one pass.
Estimating before a storm claim
Know the approximate roof area before an adjuster visits, so the numbers in the claim make sense to you.
Comparing pitch options on new builds
See how moving from 4/12 to 8/12 changes material quantities and the edge lengths.
Tips and limitations
- Check whether your province adds requirements; Ontario, Quebec, British Columbia and Alberta publish their own codes based on the NBC.
- Self-sealing modified bitumen membrane is one of the eave protection materials the code lists, alongside two plies of No. 15 felt and Type M or S roll roofing.
- Valleys on shingled roofs must be flashed over continuous sheathing.
Sources and further reading
- National Building Code of Canada 2025 (Division B, Part 9), National Research Council of Canada (Government of Canada Publications). Table 9.26.3.1 slope limits; Subsection 9.26.5 eave protection; 9.26.8 low-slope shingles.
- Codes Canada, National Research Council Canada
Frequently asked questions
What is the minimum roof pitch for asphalt shingles in Canada?
NBC Table 9.26.3.1 allows normal shingle application from a slope of 1 in 3 (4/12). Low-slope application per Subsection 9.26.8 is allowed down to 1 in 6 (2/12). Below that, shingles are not permitted.
Do I need ice and water shield on my roof in Canada?
Eave protection is required by NBC 9.26.5 on shingle, shake and tile roofs, extending at least 900 mm up the slope and to 300 mm inside the inner face of the exterior wall, unless an exception applies such as an unheated garage, a slope of 1 in 1.5 or more, or a region with 3,500 or fewer degree-days.
How many bundles of shingles do I need for a 1,500 sq ft roof?
Fifteen squares at three bundles each is 45, plus 10% waste gives 50 bundles. Measure the roof surface, not the floor area: the pitch and overhang make the roof larger than the house footprint.
Does an 8/12 roof need eave protection?
An 8/12 slope equals 1 in 1.5, which is one of the NBC exceptions, so eave protection is not required by the national code. Many roofers install it anyway in snowy regions, and your province may differ.
How do I convert roofing squares to square metres?
One square is 100 sq ft, which is 9.29 m². The calculator shows the roof area in both units.
Is there an in-depth guide to the Roofing Calculator?
Yes. “Roof Pitch, Stair Layout, AC Sizing and Running Costs Explained” covers the background, how it works, common pitfalls and worked examples. Read the full guide.
Related Tools You May Like