United Kingdom version. Set up for UK staircases: spindles between newels in millimetres, the 100 mm sphere limit from Approved Document K and marks measured along the raked handrail. US version
Spindle Spacing Calculator (UK, 100 mm Rule)
How many stair spindles fit between newel posts with equal gaps under the 100 mm sphere rule in Approved Document K, with centres to mark along the handrail.
The interactive tool loads here when JavaScript runs.
About this toolWhat is the Baluster Spacing Calculator?
In the UK the balusters on a staircase are usually called spindles, and the rule they have to meet is the 100 mm sphere: Approved Document K says that in a building that may be used by children under five, guarding to a flight of stairs should not let a 100 mm sphere pass through any opening. Homes are treated that way, so every gap between spindles has to be under 100 mm.
Enter the clear length between the newel posts along the handrail, the spindle width (41 mm square is a common stock size) and the riser and going of the stair. For a 3,000 mm rail on a 200 mm rise and 225 mm going stair, 16 spindles of 41 mm give equal 93.3 mm gaps, set out at 179.7 mm centres along the rail.
The same tool handles a landing balustrade: switch to a level rail and enter the distance between the newels. Height is a separate rule; Diagram 3.1 of Approved Document K gives 900 mm for stairs, landings and the edges of internal floors in a single family dwelling and 1,100 mm for external balconies.
- Baluster count, equal gap, on-centre spacing and first position
- IRC 4 in and 4-3/8 in, 100 mm and 125 mm presets or a custom limit
- Stair mode from rise and run or degrees, with marks along the rail
- Layout table of every centre and an elevation sketch
- Multiple identical sections; imperial fractions or millimetres
Updated
How to use the Baluster Spacing Calculator
- Choose stair rail for the flight or level rail for a landing.
- Measure the clear length between the inside faces of the newels, along the handrail for a stair.
- Enter the spindle width at its narrowest point. Turned spindles are measured at the thinnest section.
- Keep the 100 mm limit, or set a custom limit of 95 mm if the spindles are not perfectly straight.
- Enter the riser height and going, then mark the centres from one newel using the layout table.
Worked examples
Straight flight with 41 mm spindles
Input
3,000 mm between newels along the rail, 41 mm spindles, 200 mm rise and 225 mm going (41.6°), 100 mm limit
Output
16 spindles, 93.3 mm gaps, 179.7 mm centres along the rail, first centre 152.3 mm from the newel
The rail covers 2,242 mm of level run. The gap is measured level between the vertical spindles, which is why the spacing along the sloping rail is wider than the gap plus the spindle.
Landing balustrade
Input
Level rail, 1,200 mm between newels, 41 mm spindles, 100 mm limit
Output
8 spindles, 96.9 mm gaps, 137.9 mm centres
Only 3 mm under the limit. With 32 mm spindles the same landing takes 9 at 91.2 mm gaps, which gives more margin for spindles that bow.
Same flight with a 95 mm working limit
Input
3,000 mm rail, 41 mm spindles, 41.6° stair, custom 95 mm limit
Output
16 spindles, 93.3 mm gaps
The count does not change here because 16 spindles already leave 93.3 mm. Setting a working limit under 100 mm costs nothing when the layout already clears it, and adds a spindle when it does not.
Background and insight
With n balusters of width b in a clear length L there are n + 1 gaps, so gap = (L - n b) / (n + 1). Requiring gap to be no more than the limit g gives n = ceil((L - g) / (b + g)). For 96 in between posts, 1-1/2 in balusters and a 4 in limit that is 17 balusters with 3.92 in gaps at 5.42 in on centre. Marking every centre from one post, rather than stepping off the spacing, stops rounding from adding up.
The IRC (Section R312.1.3) says required guards must not have openings that allow a 4 in sphere to pass, with two exceptions: 4-3/8 in on the open side of stairs and 6 in for the triangle formed by the riser, tread and bottom rail. England uses 100 mm (Approved Document K), as does the National Building Code of Canada, and Australia's NCC uses 125 mm. On a stair the balusters are vertical, so the clear gap is measured level: the calculator works in the level run (rail length x cos of the rake) and divides back by the cosine for marks along the rail.
Common use cases
Deck and porch railings
Lay out balusters between posts with equal gaps that meet the 4 in rule.
Stair balustrades
Convert level spacing into marks along a raked handrail or stringer.
Ordering balusters
Count balusters for several identical sections in one go.
Metal and cable infill checks
Check gaps for metal pickets or glass panels against a 100 mm or 125 mm limit.
Tips and limitations
- Approved Document K also asks for guarding that children cannot readily climb, so avoid horizontal rails between the handrail and the string.
- Open-riser stairs in a home need treads that overlap by at least 16 mm and gaps that a 100 mm sphere cannot pass (Approved Document K, paragraph 1.9).
- Check the triangle between the string, the bottom rail and the first spindle as well as the gaps between spindles.
- Wales has its own Approved Document K and Scotland uses the Building Standards technical handbooks, so check the version that applies where you live.
Sources and further reading
- Protection from falling, collision and impact: Approved Document K, GOV.UK. Paragraphs 1.9, 1.39 and 3.3 (100 mm sphere, climbing) and Diagram 3.1 (guarding heights), 2013 edition.
- Approved Document K, 2013 edition (PDF), GOV.UK
Frequently asked questions
What is the maximum gap between stair spindles in the UK?
Under 100 mm. Approved Document K (paragraph 1.39 for stairs and 3.3 for other guarding) says a 100 mm sphere should not pass through any opening in guarding in a building that may be used by children under five, which covers homes.
How many spindles do I need for my staircase?
It depends on the rail length between the newels, the spindle width and the stair angle. A typical 3,000 mm rail on a 41.6° flight takes 16 spindles of 41 mm. Count each section between newels separately and add them up.
How do I space spindles on a sloping handrail?
Work out the spacing on the level and divide by the cosine of the stair angle to get the distance along the rail. The calculator does this from the rise and going, so the marks in the layout table can be measured straight along the handrail.
What height should a stair balustrade be in a house?
Diagram 3.1 of Approved Document K gives 900 mm for stairs, landings and the edges of internal floors in a single family dwelling, and 1,100 mm for external balconies and the edges of roofs. Spindle spacing and guarding height are separate checks.
Do I need to replace spindles that are 120 mm apart in an old house?
Approved Document K applies to new building work, so existing guarding is not automatically unlawful. If you replace or alter the balustrade, the new work should meet the 100 mm rule, and young children in the house are a good reason to close the gaps anyway.
Is there an in-depth guide to the Baluster Spacing Calculator?
Yes. “Baluster Spacing and the 4 Inch Sphere Rule, With the Math” covers the background, how it works, common pitfalls and worked examples. Read the full guide.
Related Tools You May Like
Free, in-browser tools that pair well with this one.