United Kingdom version. Shows pressure in bar by default, as UK plumbing does, and relates head to the 7 metre minimum set by the water company service standards in England and Wales. US version
Hydrostatic Pressure Calculator (UK): Head to Bar
Convert metres of head to bar and kPa for gravity-fed systems, loft cisterns and tanks, and compare with the 7 m static head required in England and Wales.
The interactive tool loads here when JavaScript runs.
About this toolWhat is the Hydrostatic Pressure Calculator?
British plumbers and shower makers talk in "head": the vertical height of water above an outlet. Many homes still have a cold water cistern in the loft feeding the hot cylinder and some taps, and the pressure at a tap or shower is set almost entirely by how far below the cistern's water level it sits. Each metre of head gives about 0.098 bar, so a shower head 1.5 m below the cistern gets roughly 0.15 bar before any losses in the pipework.
This version opens in bar and starts at 3 m of head, typical of a bathroom one floor below a loft cistern. The result, 0.294 bar, explains why gravity showers are gentle and why makers quote a minimum head for each product. Compare it with a mains-fed combi system: the water company has to keep at least 7 m of static head in the communication pipe to a property, which is 0.686 bar. A pumped or mains supply is a different order of pressure from a gravity system.
The same formula answers tank questions too: the pressure on the bottom of a water butt, a header tank in a heating system or an open oil tank. Enter the depth and pick the liquid.
- Gauge and absolute pressure at any depth, p = ρgh
- Presets for fresh water, seawater, brine, fuels, oil and mercury, plus custom density
- Editable atmospheric pressure and a choice of Pa, kPa, bar, MPa or psi
- Force and centre of pressure on a vertical rectangular wall or gate, with a diagram
- Metric and US units with in-place conversion, copy and share
Updated
How to use the Hydrostatic Pressure Calculator
- Enter the head: the vertical distance from the water surface in the cistern or tank down to the outlet, not the length of pipe.
- Leave the liquid on fresh water, or pick another fluid or type its density.
- Read the gauge pressure in bar; switch "Show pressure in" to kPa, psi or another unit when a datasheet asks for it.
- For the force on a tank wall or a hatch, enter its width and height in the lower panel.
Worked examples
Gravity-fed shower below a loft cistern
Input
Fresh water, head 1.5 m
Output
0.147 bar (14.7 kPa) gauge
This is the static pressure with no water flowing. Once the shower runs, friction in the pipes and the mixer valve take some of it, which is why a small head gives a weak spray.
Bathroom one floor below the loft
Input
Fresh water, head 3 m
Output
0.294 bar (29.4 kPa) gauge
Doubling the head doubles the pressure. Raising a cistern on a platform is the classic fix for a poor gravity shower; a shower pump is the other.
The water company minimum
Input
Fresh water, head 7 m
Output
0.686 bar (68.6 kPa) gauge
In England and Wales the Customer Service Standards Regulations set 7 m static head in the communication pipe as the minimum. Falls below it for an hour or more on two occasions in 28 days can bring a payment under the guaranteed standards scheme.
Rule of thumb check: 10 m of head
Input
Fresh water, head 10 m
Output
0.981 bar (98.1 kPa) gauge
Ten metres of water is just under 1 bar, which is why plumbers treat "1 bar = 10 m head" as a quick conversion. The exact figure for 1 bar is 10.2 m.
Background and insight
The relation comes from a force balance on a small column of fluid: the pressure at the bottom must support the weight of the column above it, so dp/dz = ρg. With constant density this integrates to p = p_atm + ρgh. Pascal described the consequences in the 1640s, including the hydrostatic paradox that a tall thin column exerts the same bottom pressure as a wide tank of the same depth.
For a plane surface, the resultant force equals the pressure at the centroid times the area, F = ρg h_c A. The force acts lower than the centroid, at y_cp = h_c + I_c/(h_c A), because pressure is higher at the bottom. For a rectangle starting at the surface that is two-thirds of the way down. Gauge pressure is used because atmospheric pressure usually acts on both faces of a wall and cancels.
Seawater density depends on salinity and temperature, usually between about 1020 and 1030 kg/m³ at the surface, so 1025 kg/m³ is a common design value. Standard gravity is 9.80665 m/s² and a standard atmosphere is 101.325 kPa (14.696 psi).
Common use cases
Tank and pipe pressure ratings
Find the static pressure at the bottom of a tank, a riser or a vertical pipe run.
Walls, gates and hatches
Get the resultant force and where it acts for structural or hinge design.
Level and pressure sensors
Convert a transmitter reading to liquid depth for a known density, or the reverse.
Diving and marine work
Pressure at depth in seawater in bar, psi and atmospheres absolute.
Tips and limitations
- Measure head from the water level in the cistern, not from its base or the top of the tank, and down to the outlet that matters (the shower head or the pump inlet).
- Static head is what you have with nothing running. To see what is left at a flowing tap, take off the friction loss from the Pipe Pressure Drop Calculator.
- A gravity shower and a mains-pressure combi supply differ by an order of magnitude, so check a shower's minimum head or bar rating before buying.
- Unvented cylinders and combi boilers run on mains pressure, so their performance depends on the supply in the street rather than on head.
Sources and further reading
- The Water Supply and Sewerage Services (Customer Service Standards) Regulations 2008, regulation 17G (Pressure standard), legislation.gov.uk. English water wholesalers must keep at least 7 m static head in the communication pipe.
- The Water Supply and Sewerage Services (Customer Service Standards) Regulations 2008, regulation 10 (Pressure standard), legislation.gov.uk. The same 7 m static head standard for Welsh water undertakers.
- CODATA value: standard acceleration of gravity, National Institute of Standards and Technology. 9.80665 m/s², used for p = ρgh.
Frequently asked questions
How many bar is 1 metre of head?
About 0.098 bar (9.81 kPa) for fresh water. Ten metres is 0.98 bar, so "10 metres per bar" is a close rule of thumb; 1 bar is exactly 10.2 m of fresh water.
What is the minimum water pressure a water company must provide?
In England and Wales the Water Supply and Sewerage Services (Customer Service Standards) Regulations 2008 set 7 m of static head in the communication pipe serving the property, about 0.69 bar. If it falls below that for an hour or more on two occasions within 28 days, a payment may be due, subject to exceptions such as necessary works and drought.
Why is my gravity-fed shower so weak?
Because the head is small. With the cistern 1.5 m above the shower head there is only about 0.15 bar before pipe losses. Raising the cistern, shortening the pipe run or fitting a shower pump are the usual fixes.
How do I measure the head of water in my house?
Measure the vertical distance from the water level in the loft cistern to the outlet, for example with a tape down the stairwell. Horizontal pipe runs add no head; only the height difference counts.
Does a bigger cistern give more pressure?
No. Pressure depends on depth, not on the volume of water. A bigger cistern lets a bath fill without the level dropping as far, which helps slightly, but height is what sets the pressure.
Is there an in-depth guide to the Hydrostatic Pressure Calculator?
Yes. “Hydrostatic Pressure at Depth and the Force on Walls and Gates” covers the background, how it works, common pitfalls and worked examples. Read the full guide.
Related Tools You May Like
Free, in-browser tools that pair well with this one.