Australia version. Metric and degrees, with metal sheeting worked out from cover width (762 mm corrugated by default) and cut lengths, or tiles per m², in A$. US version
Metal Roofing and Roof Tile Calculator (Australia)
Roof area in m² from the footprint and pitch, then metal sheets by cover width and cut length, lineal metres of sheeting, or concrete and terracotta tiles per m².
The interactive tool loads here when JavaScript runs.
About this toolWhat is the Roofing Calculator?
Profiled steel sheet is one of the most common roof coverings in Australia, cut to length and sold by the lineal metre. What you need to know is how many sheets fit across each slope, how long each one is, and the total lineal metres. A sheet's cover width, not its full width, decides that: corrugated profiles such as LYSAGHT CUSTOM ORB cover 762 mm.
For a 12 by 8 m gable roof with 450 mm eaves at 22.5°, that is 17 sheets a side, 34 in all, each 4.82 m long, about 171 lineal metres with 5% for laps and offcuts. A skillion carport 6 by 6 m at 5° takes nine sheets of 6.32 m.
The NCC Housing Provisions Part 7.2 sets minimum pitches for each profile and maximum spans between battens or purlins, for example 900 mm end spans and 1,200 mm internal spans for 0.42 mm corrugated. The manufacturer's figures for your exact sheet take priority, and concrete or terracotta tiles can be counted here too from their gauge and cover width.
- Gable, hip and shed roofs from footprint, overhang and pitch
- Pitch as rise in 12 or degrees, with a multiplier table
- Squares, bundles, underlayment rolls, ridge cap and drip edge in one result
- Editable bundles per square, roll coverage, cap coverage and piece length
- Imperial or metric inputs, cost per bundle, copy and share
Updated
How to use the Roofing Calculator
- Set metric units and pitch in degrees.
- Enter the footprint (length along the ridge and width) and the eave overhang.
- Choose metal sheets and enter the cover width from the profile data, or tiles with their batten gauge and cover width.
- Enter the price per lineal metre or per tile in A$ and a waste allowance.
Worked examples
Gable roof in corrugated steel
Input
12 x 8 m footprint, 0.45 m eaves, 22.5°, gable, 762 mm cover, 5% extra
Output
124.3 m²; 34 sheets (17 per side) of 4.82 m; about 171.2 lineal m
Sheets run from ridge to gutter in one length, so order each cut length rather than stock lengths.
Hip roof, same profile
Input
15 x 10 m, 0.45 m eaves, 22.5°, hip, 762 mm cover, 10% extra
Output
187.6 m²; about 270.8 lineal m; 37.1 m of ridge and hips for capping
Hip sheets are cut on the angle, so the tool gives lineal metres from the area; the supplier will produce a cutting list from the plan.
Skillion carport
Input
6 x 6 m, 0.15 m overhang, 5°, skillion, 762 mm cover, 5% extra
Output
9 sheets of 6.32 m; about 54.9 lineal m
Five degrees is the minimum pitch the maker gives for CUSTOM ORB; a lower carport needs a profile rated for low pitch.
Background and insight
The pitch multiplier is the length of a rafter per unit of horizontal run: the square root of 1 + (rise / 12)². At 6 in 12 it is 1.118, so a roof covers 11.8% more surface than its footprint; at 12 in 12 (45°) it is 1.414. Because every plane of a simple gable or hip roof has the same pitch, multiplying the total plan area by this one factor gives the whole roof area, however the planes are arranged.
Asphalt shingles are sold so that three bundles cover one square for most three-tab and many architectural products, but heavier laminated shingles can need four or five, which is why the wrapper is the final word. Nominal underlayment coverage is about 400 ft² for a roll of #15 felt, 200 ft² for #30 and around 1,000 ft² for many synthetic rolls, less once laps are taken out.
Hips and valleys need cut shingles along their full length, and dormers add both. A plain gable is often estimated at 10% waste and a cut-up hip roof at 15% or more, which is a judgment call rather than a formula.
Common use cases
Checking a reroof quote
Compare the number of squares on a contractor quote with an independent figure from the footprint and pitch.
Ordering shingles for a shed or garage
Get bundles, underlayment and drip edge for a small DIY roof in one pass.
Estimating before a storm claim
Know the approximate roof area before an adjuster visits, so the numbers in the claim make sense to you.
Comparing pitch options on new builds
See how moving from 4/12 to 8/12 changes material quantities and the edge lengths.
Tips and limitations
- Trapezoidal profiles have different cover widths from corrugated; enter the figure for the exact sheet.
- In bushfire-prone areas, roofing must also meet the BAL construction requirements for your site.
- Working on a roof is high-risk work; use edge protection or a licensed roofer.
Sources and further reading
- Part 7.2 Sheet roofing (NCC 2025 Housing Provisions), Australian Building Codes Board. 7.2.3 minimum pitches; Table 7.2.4 maximum spans.
- LYSAGHT CUSTOM ORB, BlueScope (SteelSelect). 762 mm cover width, 5° minimum pitch.
Frequently asked questions
How many Colorbond sheets do I need for my roof?
Divide the length of each slope along the gutter by the cover width and round up. A 12.9 m eave line with 762 mm corrugated sheet needs 17 sheets. Each sheet is cut to the slope length from ridge to gutter.
What is the minimum pitch for a corrugated iron roof?
For LYSAGHT CUSTOM ORB the maker gives 5° (1 in 12). NCC Housing Provisions 7.2.3 sets minimum pitches for each type of metal sheet profile, and lower-pitch roofs need a profile rated for it.
How do I calculate lineal metres of roof sheeting?
Roof area in m² divided by the cover width in metres. A 187.6 m² roof in 762 mm sheet is 246 lineal metres before waste, 270.8 with 10%.
How many roof tiles per square metre?
Divide 1,000,000 by gauge times cover width in mm. A concrete tile laid at a 330 mm gauge with a 300 mm cover is about 10.1 per m². Take both figures from the tile maker.
How far apart should roof battens be for metal sheeting?
NCC Housing Provisions Table 7.2.4 gives maximum spans by profile and thickness, for example 900 mm at the ends and 1,200 mm internally for 0.42 mm corrugated. The roofing maker's span tables apply to their product.
Is there an in-depth guide to the Roofing Calculator?
Yes. “Roof Pitch, Stair Layout, AC Sizing and Running Costs Explained” covers the background, how it works, common pitfalls and worked examples. Read the full guide.
Related Tools You May Like
Free, in-browser tools that pair well with this one.