Australia version. Set up for Australian timber framing: 450 or 600 mm stud centres, 90 x 35 mm plates and studs, lintels, wall frames 2.4 m high and lengths in metres. US version

Timber Wall Frame Calculator (Australia)

Count studs, plates and lintels for a timber wall frame at 450 or 600 mm centres, in 90 x 35 or 90 x 45 MGP10, with door and window openings in mm.

The interactive tool loads here when JavaScript runs.

About this tool

What is the Wall Framing Calculator?

Australian house frames are commonly pine, such as MGP10 in 90 x 35 or 90 x 45 mm, with studs at 450 or 600 mm centres. Under the National Construction Code, timber framing in non-cyclonic areas meets the structural requirement when it follows AS 1684.2 or the simplified AS 1684.4, and AS 1684.3 applies in cyclonic areas. Those standards set the stud, plate and lintel sizes; this calculator counts the pieces once the sizes are chosen.

This version starts with a 6.0 m external wall frame, 2.4 m high, with two 90 x 35 top plates, a door and a 1810 x 1200 mm window. At 450 mm centres it needs 31 studs with 10% extra; at 600 mm it needs 27.

Wall frames from a prefabrication plant come with their own cutting list. Use this to check a frame quote, to price a pergola enclosure, a shed or a stud wall in a renovation, or to order timber for a frame you build on site.

  • Feet-inch-fraction or metric input with live echo of the parsed value
  • Layout studs, opening deductions, kings, jacks and cripples
  • Corner and intersection studs set to your framing style
  • Plate linear feet and stock pieces, header lengths, sheathing sheets
  • Itemised stud table, copy and share link
Read the guide: How Many Studs Do I Need? Wall Framing Takeoffs Explained

Updated

How to use the Wall Framing Calculator

  1. Keep the units on metric and enter the wall length and the frame height (floor to top of the top plate).
  2. Pick 450 or 600 mm centres as the frame design or AS 1684 tables allow for your stud size, height and load.
  3. Enter the timber thickness: 35 mm for 90 x 35, 45 mm for 90 x 45. Set the top plates to two if you use two 35 mm plates.
  4. Enter each opening as its frame opening size, the lintel depth from the design, and the sill height for windows.

Worked examples

External wall frame at 450 mm centres

Input

6.0 x 2.4 m, 35 mm timber, two top plates, two corners and one wall junction (two extra studs each), one 870 x 2100 mm door, one 1810 x 1200 mm window at 900 mm sill, 190 mm lintels, two plies, 10% extra

Output

31 studs to buy (28 net) at 2295 mm; 18 m of plate (six 5.4 m lengths); lintels 2 at 940 mm and 2 at 1880 mm

Fifteen layout positions, minus five inside the openings, plus the studs at the sides of each opening, four short jack studs and the corner and junction studs.

The same frame at 600 mm centres

Input

As above, studs at 600 mm

Output

27 studs to buy (24 net)

Wider centres save four studs, but only if the AS 1684 tables or the engineer allow 600 mm for that stud size, height and roof load, and the wall lining spans 600 mm.

Background and insight

Studs are laid out from one end of the wall at a fixed spacing, so a wall of length L holds ceil(L / s) + 1 studs including the one at the far end: ten studs for a 12 ft wall at 16 in. Sixteen-inch layout lines up with 4 ft sheets every third stud; 24 in layout, used in advanced framing, lines up every second stud and saves roughly a third of the studs. Metric frames use 400 or 600 mm for the same reason with 1200 mm sheets.

A standard 8 ft wall is 97-1/8 in from floor to the top of the double top plate: three plates at 1-1/2 in plus a 92-5/8 in precut stud. That leaves room for a 96 in sheet of drywall on the wall plus the thickness of the ceiling board. Each opening gets a king stud on both sides running full height and one or more jack (trimmer) studs carrying the header; short cripples fill the layout above the header and below a window sill. Header size depends on the opening width and the load above and comes from a header span table such as IRC Table R602.7(1).

Common use cases

  • Ordering lumber for a room addition

    Total studs, plates and headers wall by wall before calling the yard.

  • Basement and garage partitions

    Count studs for non-bearing walls with a single top plate or 24 in spacing.

  • Bidding framing labour

    Use the stud and opening counts as the basis for a per-piece or per-opening price.

  • Learning wall anatomy

    See how kings, jacks, cripples and corner studs add up and where the extra studs go.

Tips and limitations

  • Order plates in lengths that suit the wall: a 6.0 m wall with three plate runs takes six 5.4 m lengths, or three 6.0 m lengths with no joins.
  • Noggings are not counted. Add a row of noggings to each bay where the frame design or the lining calls for them.
  • Keep bracing and tie-down in the plan from the start; bracing walls and their fixings are set by the frame design, not by the stud count.

Sources and further reading

  1. NCC 2025 Volume Two, Part H1 Structure (H1D6 Framing), Australian Building Codes Board. Timber framing to AS 1684.2, AS 1684.3 or AS 1684.4 as the deemed-to-satisfy route.
  2. AS 1684.2:2021 Residential timber-framed construction, Part 2: Non-cyclonic areas, Standards Australia

Frequently asked questions

Which standard covers timber wall framing in Australia?

The National Construction Code accepts timber framing designed and built to AS 1684.2 or AS 1684.4 in non-cyclonic areas and AS 1684.3 in cyclonic areas, alongside AS 1720.1 for engineered design. Queensland has its own variation of the clause. Stud, plate and lintel sizes come from the span tables in those standards.

Are studs at 450 or 600 mm centres?

Both are common. 450 mm suits plasterboard and tiling and gives a stiffer wall; 600 mm saves timber where the AS 1684 tables allow it for the stud size, height and load. The plasterboard maker also sets the maximum frame centres for each board.

What is the difference between 90 x 35 and 90 x 45 studs?

Both fit a 90 mm wall. The 45 mm section is stronger and easier to fix linings to at sheet joints, and is often used for top plates or where the tables need it. Enter the thickness you are using so the stud length and plate run come out right.

What are jamb studs and jack studs?

Jamb studs run full height beside an opening and carry the lintel. Jack studs are the short studs above a lintel and below a window sill that keep the layout going. In the calculator they appear as king and jack studs and cripples.

How long should a lintel be?

The opening width plus its bearing at each end. With one 35 mm stud under each end, an 1810 mm window needs an 1880 mm lintel. The lintel size comes from the AS 1684 tables for the opening width and what it carries.

Is there an in-depth guide to the Wall Framing Calculator?

Yes. “How Many Studs Do I Need? Wall Framing Takeoffs Explained” covers the background, how it works, common pitfalls and worked examples. Read the full guide.